Alarm / Detector & sensors

X Close


Indoor PIR With Pet Immunity
 
DG75

How to use:
At the recommended installation height of 2 meter (7ft.) to 2.7 meter (9ft.) ±10%, Digigard 75 provided full coverage from 1.5 meter (5ft.) to 121 meter (35ft.)

Avoid placing the detector in close proximity to the following source of interference, reflective surface, direct air flow from vents, fans, windows, source of steam or oil vapor, infrared light source and objects causing temperature changes such as heaters, refrigerators and ovens.

Do not place objects or furniture higher then 0.9 meter (3ft.) which a pet can climb onto (e.g. a cat on a couch) at least 2.1 meter (7ft.) away from the detector. In addition, do not aim the detector at a stairway as a pet may have access.

Specification:

Description Digigard 75
Sensor type Dual optics (2 dual opposed element sensors)
Sensor geometry Rectangular
Coverage -90°(standard) 11 meter x 11 meter (35ft. x 35ft.)
Pet immunity Up to 40kg (90lbs)
Installation height 2 meter to 2.7 meter (7ft. to 9 ft.)
Operating temperature -20°C to +50°C (-4°F to +122°F)
Voltage input Typically 11-16V DC
Current consumption 15mA maximum
Lens 2nd generation Fresnel lens, LODIFF®, segments
EMI / RFI immunity 10V/m rejection from 10MHz. to 1GHz.
Alarm output From A relay 100mA / 28V DC, N.C. or optional from C relay 5A / 28V DC, N.C./N.O.
Anti tamper switch 150mA / 28V DC, N.C.
Walk speed 0.2m/s to 3.5m/s (0.6ft./s to 11.5ft./s)
Anti tamper switch 150mA/28V DC, N.C.


 

Installation Guide

 © 2012 MAGNET Security & Automation Sdn. Bhd.